The M3-E is designed for use in industrial processes in environments with a potentially explosive atmosphere, caused by gas and dust, in compliance with ATEX Directive (94/9/ EC). In particular, the M3-E can be used in areas 1 and 2 (gas) and in areas 21 and 22 (dusts).
CATEGORY
II 2 G,D
LEVEL OF PROTECTION
Ex e II, tD A21 IP66
TEMPERATURE CLASS
Gas: T4 (275°F) Dusts: 248°F
EC CERTIFICATE
LCIE 06 ATEX
AREAS OF USE
1, 2, 21, 22
Power supply
Three-phase voltage 127/220V, 50Hz,200/346V, 60Hz; or 210/363V, 50 Hz
Polarity
2 standard poles.
Functioning
Continual service (S1) at maximum declared centrifugal force and electric power.
Centrifugal force
Up to 194 lbs. (863 N).
Insulation class
Class F (311°F).
Electric motor
Three-phase or single−phase asynchronous type. Insulated windings using vacuum encapsulating.